Knowledge Why must deionized water be treated with 0.22 μm filters before measuring particle size and PDI? Ensure DLS Accuracy
Author avatar

Tech Team · Enokon

Updated 5 days ago

Why must deionized water be treated with 0.22 μm filters before measuring particle size and PDI? Ensure DLS Accuracy


Deionized water must be processed through 0.22 micrometer microporous filters to completely eliminate minute dust and microscopic impurities before use. In the context of Dynamic Light Scattering (DLS) analysis, these background contaminants scatter light with disproportionate intensity, creating interference that makes it impossible to obtain accurate nanoscale particle size measurements or reliable Polydispersity Index (PDI) data.

In Dynamic Light Scattering (DLS), the purity of your dilution medium is a strict prerequisite for accuracy. Unfiltered background impurities act as overwhelming "noise," masking the signal from your actual sample and artificially broadening your data distribution.

The Physics of Contamination in DLS

The Disproportionate Impact of Dust

DLS instruments are extremely sensitive to light scattering. Larger particles, such as common dust or microscopic debris found in untreated water, scatter light much more intensely than the nanoscale particles you intend to measure.

If the dispersion medium (the water) contains even a few "large" impurities, their scattering signal can overshadow the signal from millions of smaller nanoparticles. This results in data that is heavily skewed toward larger sizes, rendering the measurement invalid.

Preserving PDI Accuracy

The Polydispersity Index (PDI) measures the width of your particle size distribution. A low PDI indicates a highly uniform sample.

When you introduce unfiltered water, the random impurities create artificial peaks or "tails" in the distribution data. This causes the PDI to appear much higher than it actually is, falsely suggesting that your sample is uniform when the "polydispersity" is actually coming from the dirty background.

Establishing a Zero-Interference Baseline

The Role of the 0.22 Micrometer Filter

A 0.22 micrometer filter is the industry standard for removing bacteria and fine particulates. By passing deionized water through this specific pore size, you effectively "scrub" the medium of physical contaminants.

Ensuring Signal Integrity

The goal is to ensure that the only things scattering light in the cuvette are the particles you synthesized or isolated. By filtering the water, you ensure that the background signal is negligible, allowing the detector to capture the true behavior of your nanoscale sample.

Common Pitfalls and Considerations

Filter Quality Matters

Not all filters are created equal. Using a low-quality filter can introduce new contaminants into the water, such as fibers or leaching chemicals, which defeats the purpose of filtration.

The "False Clean" Assumption

Do not assume deionized water is "clean" just because it has high resistivity. Resistivity measures ionic content, not particulate content. High-quality deionized water can still be full of non-conductive dust that is invisible to a resistivity meter but blinding to a DLS instrument.

Making the Right Choice for Your Goal

To ensure your DLS data stands up to scrutiny, you must standardize your sample preparation.

  • If your primary focus is Accurate Sizing: Always filter the solvent (water) separately before introducing your sample to prevent artificial skewing of the mean diameter.
  • If your primary focus is Low PDI: Treat filtration of the medium as critical as the synthesis itself; a narrow distribution cannot be proven against a noisy background.

Filtration is not an optional step for "better" results; it is a fundamental requirement for valid nanoscale measurement.

Summary Table:

Feature Without 0.22μm Filtration With 0.22μm Filtration
Background Noise High (Dust & microscopic debris) Minimal (Clean baseline)
Signal Integrity Overwhelmed by large impurities True sample behavior captured
Sizing Accuracy Heavily skewed toward larger sizes Precise nanoscale measurement
PDI Reliability Artificially high/broad Accurate distribution width
Data Validity Often invalid/unreliable Scientifically sound

Elevate Your Product Quality with Enokon’s Manufacturing Expertise

Just as precision filtration is essential for accurate lab data, professional manufacturing is the key to a successful product line. Enokon is your trusted brand and manufacturer, offering premium wholesale transdermal patches and expert custom R&D solutions tailored to your needs.

Our comprehensive range of transdermal drug delivery products (excluding microneedles) includes:

  • Advanced Pain Relief: Lidocaine, Menthol, Capsicum, Herbal, and Far Infrared patches.
  • Specialized Care: Eye Protection, Detox, and Medical Cooling Gel patches.

Partner with a manufacturer that prioritizes quality and scientific integrity. Contact us today to start your custom project!

References

  1. Onyinye Okpalaku. Evaluating some Essential Oils-Based and Coconut Oil Nanoemulgels for the Management of Rheumatoid Arthritis. DOI: 10.33263/lianbs123.075

This article is also based on technical information from Enokon Knowledge Base .

Related Products

People Also Ask

Related Products

Detox Foot Patches for Detoxification

Detox Foot Patches for Detoxification

The main ingredient of detox foot patch is the bamboo vinegar powder, which was distilled by bamboo vinegar liquid by using modern high technology. The detox foot patch can dispelling toxins,clear odour, Bamboo vinegar extract’s cell is tiny, it has high penetration,can remove dirty things and toxin deeply in human body.

Cooling Fever Patches Color Change Cold Fever Patch

Cooling Fever Patches Color Change Cold Fever Patch

Fever Cooling Patch – Summer Cooling Gel Pads Antipyretic Patches Forehead Cooling Sticker Sheets Suitable for Adults and Children Cooling gel patch for body fever is produced according to TDDS technical. And it is a soft gel strip that has been especially designed to relieve discomfort from baby/child/Adult fevers and other minor ailments with a powerful cooling effect that lasts up to 8 hours. upgrade color change function help to monitor the body temprature change without use thermometer.


Leave Your Message